Circular elevator control cables with earthing

Circular elevator control cables with earthing
Product Detailed
Related Categories:Control Cables
Circular elevator control cables with earthing 1.TLC 2.CCC 3.ISO

 Circular elevator control cables with earthing

1.Purposes:Use for wiring of elevator control circles

2.Characteristic:-PVC insulation,

                                -PVC sheath

                                -Rated voltage AC 300/500V, rated temperature 70C°

                                -Steel cable

3.Product standard:GB5023.6-1997/227 IEC 71 F(TWB)/60227 IEC 71 F(TVVB)

1-Copper conductor; 2-PVC insulation; 3-PVC sheath

Electric cable summarized information

Conductor core and nominal cross-sectional area(mm2)

Insulati on thickness(mm)

Thickness of sheath(mm)

Average outer Diameter Limit(mm)

Min RESIST at 70°C(MΩ.km)

Lower

Upper

6×0.75

6×1

6×1.5

6×2.5

0.4

0.6

0.7

0.8

0.8

1.0

1.1

1.2

9.6

11.0

13.3

15.8

6.5

8.7

9.9

12.4

0.011

0.010

0.010

0.009

7×0.75

7×1

7×1.5

0.4

0.6

0.7

0.8

1.1

1.1

9.6

11.0

13.3

6.5

8.7

9.9

0.011

0.010

0.010

8×0.75

8×1

8×1.5

0.4

0.6

0.7

1.0

1.2

1.2

10.6

13.2

14.2

7.5

9.5

10.8

0.011

0.010

0.010

10×0.75

10×1

0.4

0.6

1.0

1.2

13.2

14.5

9.0

11.7

0.011

0.010

12×0.75

12×1

0.4

0.6

1.2

1.2

13.2

14.8

9.5

11.9

0.011

0.010

15×0.75

15×1

0.4

0.6

1.2

1.2

14.0

15.5

10.7

11.6

0.011

0.010

Conductor core and nominal cross-sectional area(mm2)

Insulati on thickness(mm)

Thickness of sheath(mm)

Average outer Diameter Limit(mm)

Min RESIST at 70°C(MΩ.km)

Lower

Upper

16×0.75

16×1

0.4

0.6

1.2

1.3

14.0

15.5

10.7

11.6

0.011

0.010

19×0.75

19×1

0.4

0.6

1.2

1.2

15.0

17.8

11.3

14.1

0.011

0.010

20×0.75

20×1

0.4

0.6

1.2

1.2

15.5

18.3

11.6

14.6

0.011

0.010

24×0.75

24×1

0.4

0.6

1.2

1.2

17.0

20.5

13.5

16.8

0.011

0.010

25×0.75

25×1

0.4

0.6

1.2

1.2

17.1

20.8

13.6

16.8

0.011

0.010

30×0.75

30×1

0.4

0.6

1.4

1.4

19.5

22.6

14.3

18.1

0.011

0.010

37×0.75

37×1

0.4

0.6

1.4

1.4

21.6

23.0

15.5

19.0

0.011

0.010

40×0.75

40×1

0.4

0.6

1.4

1.4

21.8

25.5

16.2

20.6

0.011

0.010

41×0.75

41×1

0.4

0.6

1.4

1.4

22.5

27.0

16.8

21.6

0.011

0.010

Circular elevator control cables with earthing